The Next Generation Real Time Analyzer System

The foundation of the Pure Analyzer System is the Pure Analyzer Essential, with a comprehensive range of analyzer options for any imaginable audio analysis and measurement, which can be expanded for more specific utilization with up to three add-on modules; Live, Metering/Loudness and Multichannel/Surround.

Pure Analyzer Essential

The Pure Analyzer Essential is the core of the Pure Analyzer System, and is required in order to run any of the add-on modules; Live, Metering/Loudness, Multichannel/Surround.

Main Features

  • Basic metering with Peak / Basic RMS meter
  • Phase Meter
  • Real-time Spectrum Analyzer
  • Spectrogram Display
  • Vector Scope
  • Flux:: Nebula Stereo
  • Oscilloscope

Pure Analyzer Metering/Loudness Add-on

The Metering and Loudness add-on module provides an extensive set of measurement tools well adapted for Broadcast and Post Production facilities, presenting the metering tools for a vast range of standards such as True Peak, RMS, ITU-1770, EBU-R128 (PLOUD), history and more.

Main Features

  • Fully customizable and configurable meters (to conform to existing/future standards and recommendations)
  • EBU R128 / PLOUD
    ITU-R BS.1770 True Peak Default and user presets
  • Dolby Dialogue IntelligenceTM
  • Real-time metering history
  • Real-time metering statistics
  • Offline metering statistics

Audio I/O and the SampleGrabber Plug-in

The Pure Analyzer System has full support for standard hardware I/O with ASIO and Core Audio. In addition to this, a plug-in called SampleGrabber, available in all standard plug-in formats, is provided. The SampleGrabber plug-in can be inserted into the insert chain on any DAW or Digital Mixing Console supporting standard plug-ins, where it grabs the source/response audio signal and send it through the network using the ZeroConf/Apple Bonjour protocol to the Pure Analyzer stand-alone app that analyzes the audio in real time.

Pure Analyzer Live Add-on

The Live add-on module provides the elements needed to assist the live sound engineer in speaker array calibration tasks with; delay finder, level, meter, transfer function magnitude, phase and coherence spectra, impulse response, as well as snapshot facilities.

Main Features

  • LEq
  • Multi-Channels reference support (up to 8 with the multichannel option)
  • Multi-Microphone support (up to 16 with the multichannel option)
  • Meters fully customizable to make the matching as close as possible to the norm
  • SPL unit with calibration tools
  • Signal Generator
  • Sample accurate Delay Finder
  • Impulse Response
  • Transfer Function
  • Snap Shot, unlimited (with multi-project support)

Pure Analyzer Multichannel/Surround

The Multichannel and Surround add-on module provides a vast range of measurement tools for comprehensive analysis of multichannel audio environments. In addition to standard spectrum analyzer and metering tools, an innovative set of spectrum tools, Flux:: Nebula, presenting frequency and scope over space in a fashion never seen before.

Main Features

  • General additions
    • Analysis of up to 16 channels simultaneously
    • Adds Multi-Microphone support for Pure Analyzer Live
  • Flux:: Nebula Surround, providing real-time visualization of the the audio content in the surround space-frequency domain.
  • Speaker mode, supporting any type of surround configuration (4.0, 5.0, 5.1, 6.0, 7.0, 7.1 etc…)
  • Inter-channel phase correlation

Pure Analyzer Essential

 

Pure Analyzer Essential, comprehensive range of analyzer options, three add-on modules for specific utilization; Live, Metering/Loudness and Multichannel/Surround

 

 

359 €

 

Buy now

 

* We offer a 50% academic discount, based on the full MSRP, for students, teachers and schools on all our products. Click here to apply.

 

  • Live option: 179 €

  • Metering option: 179 €

  • Multichanel option: 179 €

All Features

Pure Analyzer Essential

ITU-R BS.1770 / EBU R128 Compliant

Basic metering; Peak meter, Basic RMS meter, Fully customizable scale and ballistics

Phase meter

Weighting filters; ITU-R BS.1770-2 (K-weighting), ANSI A, ANSI B, ANSI C

Real-time spectrum analyzer:

  • Standard FFT or unique Flux:: Spectrum representation
  • Block size up to 64 K
  • Configurable analysis window; Rectangular, Barlett, Blackman, Hamming, Hann
  • Real Time waterfall (see “slide” option in spectrum setup)
  • Amplitude or power frequency scaling
  •  Time-averaging; Continuously running, Fill/freeze refresh/display cycle, User-adjustable length up to 200 frames
  •  Max (accumulated) or running mode
  •  Display channels sum or a number of channels, user-selected
  • User-adjustable fixed range or automatic range
  • Simultaneous display of: Raw, full-resolution curve, Smoothed curve with user-adjustable detail setting, Peak curve
  • Independently adjustable curve ballistics
  • Peak tracking with user definable frequency range and several display variations
  • Keyboard and mouse frequency-axis zoom
  • Fully-customizable curve visual options

Spectrogram Display

  • Color modes; Power grading, Frequency grading
  • Range Min / Max

Vector Scope

  • Internal processing up to 768 kHz
  • Auto-scaling
  • Fully adjustable display; Blending, Fading, Blurring, Scaling
  • Several color modes; Static color, Power grading, Dynamic grading, Power + Dynamic grading

Nebula stereo (Front projection only)

Unique spectrum over space scope, providing real-time visualization of the the audio content in the stereo space-frequency domain.

  • Auto-scaling with user adjustable ballistics
  • Focus Control
  • Linear or logarithmic blending
  • Fully adjustable display; Fading / persistence, Blurring, Scaling
  • Choice of color modes
  • Power grading: color varies according to signal power
  • Dynamic grading: color varies according to signal dynamics
  • Power/dynamic grading: combines both previous modes
  • Frequency grading: color varies according to frequency
  • Channel-selection with surround input content

Oscilloscope; Multi-channel, Zero-crossing trigger

 

 

Live Add-on Option

 LEq

Multi-Channels reference support (up to 8 with multichannel option)

  • Individual channel selection, Summation mode

Multi-Microphone support (up to 16 with multichannel option)

  • Individual channel selection, Summation mode

Meters fully customizable to make the matching as close as possible to the norm; Color, Scaling, Integration time, Reference level, Hold

SPL unit with calibration tools

Signal Generator; Pink noise, White noise, Sine, Linear sweep, Log. sweep

Sample accurate Delay Finder; Allow very long delay detection, Time translation, Distance translation

Impulse Response; Real time short IR or long up to 10 second, Time averaging with confidence level, Auto Range, Zoom, Peak tracking with ability to send it to the delay compensation

Transfer Function

  • Analysis resolution up to 64K
  • Overlapping control
  •  Time averaging with Custom-able Length up to 200 frames
  • Coherence curve
  •  Display type; Full resolution, Smoothed, Both
  • Smoothing detail
  • Color and pen width
  •  Magnitude curve
  •   dB Range (-6/6dB to -48/48dB)
  •  Auto Range
  •  Vector or RMS Mode
  •   Display type; Full resolution, Smoothed, Both
  •  Smoothing detail
  •  Color and pen width
  •  Phase curve
  •  Display type; Full resolution, Smoothed, Both
  • Specific phases curve
  • Smoothing Detail; Threshold, Method passes, Use coherence information
  • Color and pen width
  •  Global color grading options
  •   Zoom

Snap Shot, unlimited (multi-project support)

  • Transfer function; Coherence, Magnitude, Phase
  • Spectrum; Summed. Channel independent
  •  Invert (“Iv” button) function available on Transfer Function Magnitude
  •  Impulse Response
  •  Automated Sweep Snap shot to take a snap shot with a log sweep even while using pink noise
  •  Average Snapshot created from any pre-selected snapshots

 

 

 

 

 

Metering Add-on Option

 All meters are fully customizable and configurable to conform to existing and future standards and recommendations

  • Scaling, Ballistics, Reference level, Peak-hold, Cosmetics

 EBU R128 / PLOUD

  • Momentary loudness, Short-term, Integrated, Range

 ITU-R BS.1770 True Peak Default and user presets

  • K-System, VU Meter, DIN, PPM Nordic, PPM BBC, PPM EBU

Dolby Dialogue Intelligence TM

With the Dialogue Intelligence enabled the display of other Loudness values is compensated to make sure meter readings are consistent.

Real-time metering history

  • Fully customizable
  • Scaling, Ballistics, Reference level, Peak-hold, Cosmetics
  • Peak, True Peak
  • RMS (PPM)
  • Dynamics (crest factor)
  •  Momentary loudness
  •  Short-term loudness

 Real-time metering statistics

  • Peak: min, mean, max
  • True Peak: min, mean, max
  • Rms (PPM): min, mean, max
  • Loudness: Momentary, Short, Integrated and Range
  • True Peak incident list with customizable threshold
  • Export to text

Offline metering statistics

  • Offline file-processing
  • Multi-files support (with automatic channel type detection from file name)
  • Multi-Reels
  • Up to 16 channels
  • Peak: min, mean, max
  • True Peak: min, mean, max
  • Rms (PPM): min, mean, max
  • Loudness: Momentary, Short, Integrated and Range
  • True Peak incident list with customizable threshold
  • Export to text

 

 

Multichannel Add-on Option

General additions

  • Analysis of up to 16 channels simultaneously
  •  Adds Multi-Microphone support for Pure Analyzer Live

Nebula surround (top view)

Unique spectrum over space scope, providing real-time visualization of the the audio content in the surround space-frequency domain.

Speaker mode

  • Supports any type of surround configuration (4.0, 5.0, 5.1, 6.0, 7.0, 7.1 and more…)
  • Music: standard music configuration (LR: -30°/-30°, Rear : -110°/-110°)
  • Equidistant: equidistant speaker configuration
  • Square
  • Theatre: square with addition of rear speaker, for real theatre simulation

Auto-scaling and ballistics

Choice of linear and logarithmic blending

Full control over display; Fading / persistence, Blurring, Scaling, Particle count

Color modes

  • Power grading: color varies according to signal power
  • Dynamic grading : color varies according to signal dynamics
  • Power/dynamic grading : combines both previous modes
  • Frequency grading : color varies according to frequency

Other

  • Inter-channel phase correlation

Compatibility

                           

Specifications

The Pure Analyzer Essential is required in order to run any of the add-on modules
– Pure Analyzer Metering
– Pure Analyzer Live
– Pure Analyzer Multichannel.

The add-on options are not compatible with the Studio Session Analyzer (included in the Studio Session Pack bundle).

  • Mono and Stereo analysis
  • Sample rates up to 384 KHz
  • Network support with the SampleGrabber plug-in (Password-protected audio stream encryption available)
  • Extremely efficient OpenGL based graphics rendering engine, capable of up to 120 fps
  • Independent display and time-code frame rates
  • Auto-pause controlled by user-defined threshold

Pure Analyzer is built around Flux::’s new 2D/3D efficient graphic engine, which employs full GPU-acceleration utilizing an OpenGL 2.0 compliant graphics card.

In order to experience the outstanding graphical response in Pure Analyzer and to fully take advantage of the software’s analysis capabilities, using a modern nVidia or ATI Radeon graphics card is recommended.
Older, and other less efficient graphics cards do not have the required performance and specifications, and will offload too much work to the CPU.

The processor is an important factor as well, and we recommend using at least and Intel Core 2 Duo, Core i5 or newer architecture processor. AMD processors are also supported, but might exhibit lower performance, as they do not offer the same capabilities and optimizations as Intel CPUs.

GPU: AMD/ATI Radeon or nVidia video-card. Intel integrated graphics are tested and works, but with limited capabilites, thus should be avoided.

Minimum requirements

  • CPU: Intel Core 2 Duo @ 1.6 GHz
  • GPU: OpenGL 2.0 or superior compatible, with pixel-shader support

Recommended configuration

  • CPU: Intel Core i5 @ 1.7 – 2.2 GHz or better
  • GPU: AMD/ATI Radeon or nVidia. Intel integrated graphic-cards are tested and works, but with limited capabilites.

Common requirements

  • An iLok account (no iLok USB key required).

Notes
Please make sure that the latest version of vendor-provided optimized drivers are installed for your graphics card. Generic drivers may contain bugs and are in general less up-to-date with optimizations presented in drivers specific to your particular graphics card model.

Pure Analyzer Application

Operating Systems

  • Windows – 7 SP1, 8, 8,1 and 10 in 64 bits only.
  • Mac OS X (Intel) – All versions from the 10.7.5 in 64 bits only.

Hardware I/O support

  • ASIO (Windows)
  • Core Audio (Mac OS X)

SampleGrabber plug-in

Windows – 7 SP1, 8, 8,1 and 10 in 64 bits only.

  • VST (2.4)
  • AAX Native 64 bits
  • AAX DSP (in Pro Tools 11 AAX DSP in 64 bit only)

Mac OS X (Intel) – All versions from the 10.7.5 in 64 bits only.

  • AU
  • VST (2.4)
  • AAX Native
  • AAX DSP (in Pro Tools 11 AAX DSP in 64 bit only)

Windows 32 bit

  • FluxTAnalyzer-x86.exe
  • FluxTAnalyzer-f64-x86.exe

Windows 64 bit

  • FluxTAnalyzer-x64.exe
  • FFluxTAnalyzer-f64-x64.exe

Mac OS X 64 bit

  • FluxTAnalyzer
  • FluxTAnalyzer-f64

The f64 Pure Analyzer application works internally in 64bit float, while the non f64 version works internally in 32bit float, it’s a minor difference in precision, with the 64bit version consuming more processing resources.

The 32bit version is already very precise, and more than enough for all common everyday applications. The 64bit version is provided for very specific applications; that sometimes may require extreme detail in the analysis.

A graphic card fully supporting OpenGL 2.0 is required.

  • Mac OS X: OpenGL 2.0 required – Mac Pro 1.1 & Mac Pro 2.1 are not supported.
  • Windows: If your computer has an ATi or NVidia graphics card, please assure the latest graphic drivers from the ATi or NVidia website are installed.

In order to use the software an iLok.com user account is required (the iLok USB Smart Key is not required).

Basic Requirement (Mandatory!)

The Pure Analyzer Essential is required in order to run any of the add-on modules
– Pure Analyzer Metering
– Pure Analyzer Live
– Pure Analyzer Multichannel.

The add-on options are not compatible with the Studio Session Analyzer (included in the Studio Session Pack bundle).

Processing
  • Mono and Stereo analysis
  • Sample rates up to 384 KHz
  • Network support with the SampleGrabber plug-in (Password-protected audio stream encryption available)
  • Extremely efficient OpenGL based graphics rendering engine, capable of up to 120 fps
  • Independent display and time-code frame rates
  • Auto-pause controlled by user-defined threshold
System Requirements

Pure Analyzer is built around Flux::’s new 2D/3D efficient graphic engine, which employs full GPU-acceleration utilizing an OpenGL 2.0 compliant graphics card.

In order to experience the outstanding graphical response in Pure Analyzer and to fully take advantage of the software’s analysis capabilities, using a modern nVidia or ATI Radeon graphics card is recommended.
Older, and other less efficient graphics cards do not have the required performance and specifications, and will offload too much work to the CPU.

The processor is an important factor as well, and we recommend using at least and Intel Core 2 Duo, Core i5 or newer architecture processor. AMD processors are also supported, but might exhibit lower performance, as they do not offer the same capabilities and optimizations as Intel CPUs.

System Recommendations

GPU: AMD/ATI Radeon or nVidia video-card. Intel integrated graphics are tested and works, but with limited capabilites, thus should be avoided.

Minimum requirements

  • CPU: Intel Core 2 Duo @ 1.6 GHz
  • GPU: OpenGL 2.0 or superior compatible, with pixel-shader support

Recommended configuration

  • CPU: Intel Core i5 @ 1.7 – 2.2 GHz or better
  • GPU: AMD/ATI Radeon or nVidia. Intel integrated graphic-cards are tested and works, but with limited capabilites.

Common requirements

  • An iLok account (no iLok USB key required), or a Flux:: dongle and a free USB port to connect the dongle.

Notes
Please make sure that the latest version of vendor-provided optimized drivers are installed for your graphics card. Generic drivers may contain bugs and are in general less up-to-date with optimizations presented in drivers specific to your particular graphics card model.

Compatibility

Pure Analyzer Application

Operating Systems

  • Windows – 7 SP1, 8, 8,1 and 10 in 64 bits only.
  • Mac OS X (Intel) – All versions from the 10.7.5 in 64 bits only.

Hardware I/O support

  • ASIO (Windows)
  • Core Audio (Mac OS X)

SampleGrabber plug-in

Windows – 7 SP1, 8, 8,1 and 10 in 64 bits only.

  • VST (2.4)
  • AAX Native 64 bits
  • AAX DSP (in Pro Tools 11 AAX DSP in 64 bit only)

Mac OS X (Intel) – All versions from the 10.7.5 in 64 bits only.

  • AU
  • VST (2.4)
  • AAX Native
  • AAX DSP (in Pro Tools 11 AAX DSP in 64 bit only)
Installed Application Files

Windows 32 bit

  • FluxTAnalyzer-x86.exe
  • FluxTAnalyzer-f64-x86.exe

Windows 64 bit

  • FluxTAnalyzer-x64.exe
  • FFluxTAnalyzer-f64-x64.exe

Mac OS X 64 bit

  • FluxTAnalyzer
  • FluxTAnalyzer-f64

The f64 Pure Analyzer application works internally in 64bit float, while the non f64 version works internally in 32bit float, it’s a minor difference in precision, with the 64bit version consuming more processing resources.

The 32bit version is already very precise, and more than enough for all common everyday applications. The 64bit version is provided for very specific applications; that sometimes may require extreme detail in the analysis.

Hardware Requirements

A graphic card fully supporting OpenGL 2.0 is required.

  • Mac OS X: OpenGL 2.0 required – Mac Pro 1.1 & Mac Pro 2.1 are not supported.
  • Windows: If your computer has an ATi or NVidia graphics card, please assure the latest graphic drivers from the ATi or NVidia website are installed.
Software Licence Requirements

In order to use the software an iLok.com user account is required (the iLok USB Smart Key is not required).